Agilent 240Z / 280Z is a modern generation of atomic absorption spectrometers with electrothermal atomization and graphite cuvette.
AAC 240Z/280Z presuppose the installation of four and eight lamps, respectively. The lamps are selected automatically by means of a low-inertia mirror.
Agilent 240Z/280Z atomic absorption spectrometers confidently demonstrate the highest sensitivity and accuracy in the field of atomic spectrometry. Zeeman background correction and a constant temperature zone in the GTA120 Zeeman graphite furnace, as well as intuitive Windows-based software, provide excellent performance with easy operation.
| Agilent 240Z |
Agilent 280Z |
|
| Spectral RANGE |
185-900 nm
|
|
| OPTIC |
Fully protected, quartz DUSTING |
|
| Slit WIDTH |
0.2 nm; 0.5 nm; 1.0 nm; 0.5 nm with reduced height (R) |
0.1 nm; 0.2 nm; 0.5 nm; 1.0 nm; + 0.2 R; 0.5 R; 1, 0R |
| MONOCHROMATOR |
0.25 m Czerny-Turner. 6-order holographic grid, 1200 lines/mm |
0.33 m Czerny-Turner. 6-order holographic grid, 1800 lines / mm |
| Accuracy of setting the wave LENGTH |
±0.04 nm |
±0.035 nm |
| lamp location |
4 fixed sockets. The lamps are arranged in a fan, the lamp selection is carried out by a low-inertia MIRROR |
8 fixed sockets. The lamps are arranged in a fan, the lamp selection is carried out by a low-inertia MIRROR |
| lamp Selection |
AUTOMATIC |
|
| ULTRALAMP Module |
Option. Ability to work with high intensity lamps (Ultra Lamp) up to 4 pcs. x000D_ |
Built-in module for 2 lamps. Ability to work with high intensity lamps (Ultra Lamp) up to 4 pcs |
| Background CORRECTOR |
5 ms in the range 0-2.3 A 185-900 nm. Transverse Zeeman correction, the ability to vary the strength of the magnetic field |
5 ms in the range 0-2.5 A 185-900 nm. Transverse Zeeman correction, the ability to vary the strength of the magnetic field |
| Atomizator |
Graphite furnace GTA 120 heating technology Constant Temperature Zone – temperature spread <50 °С в любом направлении кюветы на расстоянии до 1 см |
|
| Monitoring the sample entry PROCESS |
Mirror (video camera option) |
Built-in Video CAMERA |
| cuvet service life |
>500 flashes on the definition of medi |
|
| Additional Program FEATURES |
Optimization of the furnace operation without operator involvement reduces the detection limit by 2-3 time |
|
| DETECT |
Latest generation Photomultiplier: RS955 |
Latest generation Photomultiplier: proprietary Varian |
| Management |
External computer control in |
|
| PROGRAMMER |
Russified, easy-to-USE | |